Stockyard Prices Tracker

Swine Barn Equipment Inspection Form

Hogs are hard on equipment, and equipment failures are hard on hogs. A plugged waterer on a hot afternoon or a failed fan can hurt performance within hours. A regular walk through the barn, done the same way each time, catches most problems while they are still cheap.

Water first, always

Check every drinker or nipple for flow and for leaks. A weak flow means pigs drink less and eat less. A leak soaks bedding and floors and invites disease. Look at pressure, filters and lines, and clean or replace what is clogged. Pigs that are fed well but short on water lose performance quickly, so water is the first stop in the walk.

Feeders and augers

Look for worn or bridged feeders, broken adjusters and feed that has caked. Check that feeder gaps allow proper flow without waste. Listen to the auger and motor for grinding or unusual noise. Feed wasted on the floor is money lost, and moldy feed in a corner is a health problem.

Ventilation and heat

Ventilation is the part that kills pigs when it fails. Test fans, inlets, curtains and controllers on a routine schedule, not only when it gets hot. Make sure thermostats read accurately and that alarms and backup power work. Dust and cobwebs on fan blades cut airflow. If you rely on a generator or alarm system, test it under load rather than assuming it will start. The OSHA agriculture pages are a useful safety reference.

Gates, floors and pen hardware

  • Latches that hold against a determined pig
  • Floors and slats free of cracks, broken edges and sharp metal
  • Solid footing in alleys and loading chutes
  • Loose bolts, protruding wire and broken panels repaired at once

Injured animals mean lost gain, and a broken gate can mix groups that were meant to stay apart.

Electrical and safety

Inspect wiring, outlets and light fixtures for damage, moisture and rodent chewing. Swine buildings are humid and corrosive, so electrical equipment wears out sooner than you expect. Keep lockout procedures in mind when you service augers and fans; see OSHA lockout and tagout. Do not do electrical repairs yourself unless you are qualified.

Keeping a record

Write down what you found and what you fixed, even briefly. A trend of repeated trouble with the same fan or waterer tells you it is time to replace it. The livestock equipment inspection checklist and the livestock pipeline inspection form take the same approach for other systems. If problems keep coming back, call your equipment dealer or your vet to look at how the barn is performing, because sometimes the cause is not the equipment at all.

General information only. Follow the operator's manual and your dealer's service guidance for your specific machine.

Sources: OSHA Agriculture · OSHA Lockout/Tagout